Search results for "Knee joint"

showing 10 items of 177 documents

In response to the article published by Fukaya et al., entitled: “Relationships between the center of pressure and the movements of the ankle and kne…

2017

International audience

0301 basic medicinemedicine.medical_specialtyKnee JointMovementOsteoarthritisKnee Jointbiomechanicsknee osteoarthritisBiomechanical Phenomena[ SDV.MHEP.RSOA ] Life Sciences [q-bio]/Human health and pathology/Rhumatology and musculoskeletal system03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationCenter of pressure (terrestrial locomotion)center of pressuremedicineHumansOrthopedics and Sports MedicineIn patientGaitComputingMilieux_MISCELLANEOUS030203 arthritis & rheumatologybusiness.industryBiomechanicsknee braceOsteoarthritis Kneemedicine.diseaseBiomechanical Phenomenalocomotion030104 developmental biologymedicine.anatomical_structureAnkleAnklebusinessAnkle JointMedial knee
researchProduct

Biplanar ultrasound investigation of in vivo Achilles tendon displacement non-uniformity

2019

The Achilles tendon is a common tendon for the medial and lateral gastrocnemius and soleus muscles. Non‐uniform Achilles tendon regional displacements have been observed in vivo which may result from non‐uniform muscle loading and intratendinous shearing. However, prior observations are limited to the sagittal plane. This study investigated Achilles tendon tissue displacement patterns during isometric plantarflexor contractions in the coronal and sagittal planes. Fourteen subjects (5 female, 9 male, 26 ± 3 year) performed maximal isometric plantarflexor contractions with the knee in full extension and flexed to 110°. An ultrasound transducer positioned over the free Achilles tendon collecte…

030110 physiology0301 basic medicinemusculoskeletal diseasesIsometric exerciseKnee JointArticle03 medical and health sciences0302 clinical medicineIn vivoMedicineDisplacement (orthopedic surgery)ta315sub-tendonAchilles tendonultrasoundbusiness.industryUltrasoundultraääni030229 sport sciencesAnatomymusculoskeletal systemSagittal planemedicine.anatomical_structurespeckle trackingCoronal planetriceps suraeultraäänitutkimuskantajännebusiness
researchProduct

Prognosis of Pain and Physical Functioning in Patients With Knee Osteoarthritis: A Systematic Review and Meta-Analysis

2016

Objective To systematically summarize the literature on the course of pain in patients with knee osteoarthritis (OA), prognostic factors that predict deterioration of pain, the course of physical functioning, and prognostic factors that predict deterioration of physical functioning in persons with knee OA. Methods A search was conducted in PubMed, CINAHL, Embase, Psych-INFO, and SPORTDiscus up to January 2014. A meta-analysis and a qualitative data synthesis were performed. Results Of the 58 studies included, 39 were of high quality. High heterogeneity across studies (I(2) >90%) and within study populations (reflected by large SDs of change scores) was found. Therefore, the course of pain a…

030203 arthritis & rheumatologymedicine.medical_specialtybusiness.industryOsteoarthritisCINAHLKnee Jointmedicine.diseaseComorbidityPreferred walking speed03 medical and health sciences0302 clinical medicineKnee painPhysical medicine and rehabilitationRheumatologyMeta-analysisPhysical therapyMedicine030212 general & internal medicinemedicine.symptombusinessPsychosocialArthritis Care & Research
researchProduct

Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla

2009

Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…

AdultCartilage ArticularGadolinium DTPAMalemusculoskeletal diseasesdGEMRICmedicine.medical_specialtyIntraclass correlationBiomedical EngineeringContrast MediaKnee JointSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRheumatologymedicineHumansFemurOrthopedics and Sports MedicineTibiaRadionuclide Imaging030222 orthopedicsReproducibilitybusiness.industryCartilageReproducibility of ResultsMiddle AgedImage Enhancementmusculoskeletal systemMagnetic Resonance ImagingReproducibilityKnee jointSagittal planeCartilagemedicine.anatomical_structureProteoglycanFemalePatellaRadiologybusinessNuclear medicineOsteoarthritis and Cartilage
researchProduct

Facilitating cartilage volume measurement using MRI.

2010

To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.Ten knees were scanned with a 1.5T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5mm, 3.0mm and 5.0mm slices using the Argus software application. Accuracy and time effectiveness served as control parameters.Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6+/-127.7s and 379.1+/-117.6s to 214.9+/-109.9s and 213.9+/-102.2s to 122.1+/-60.1s and 126.8+/-56.2s and for the medial tibial platea…

AdultCartilage ArticularMaleKnee JointLateral tibial plateauArticular cartilageYoung AdultVolume measurementImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingControl parametersObserver VariationTibiabusiness.industryCartilageGeneral MedicineAnatomyMagnetic Resonance Imagingmedicine.anatomical_structureFemalebusinessVolume (compression)Biomedical engineeringGradient echoEuropean journal of radiology
researchProduct

EMG-Assisted Muscle Force Driven Finite Element Model of the Knee Joint with Fibril-Reinforced Poroelastic Cartilages and Menisci.

2019

Abnormal mechanical loading is essential in the onset and progression of knee osteoarthritis. Combined musculoskeletal (MS) and finite element (FE) modeling is a typical method to estimate load distribution and tissue responses in the knee joint. However, earlier combined models mostly utilize static-optimization based MS models and muscle force driven FE models typically use elastic materials for soft tissues or analyze specific time points of gait. Therefore, here we develop an electromyography-assisted muscle force driven FE model with fibril-reinforced poro(visco)elastic cartilages and menisci to analyze knee joint loading during the stance phase of gait. Moreover, since ligament pre-st…

AdultCartilage ArticularMaleKnee JointTibiaElectromyographyFinite Element Analysismusculoskeletal systemModels BiologicalElasticityArticleMechanical engineeringBiomechanical PhenomenaHumansComputer SimulationMeniscusFemurStress MechanicalMuscle Skeletalhuman activitiesPorosityBiomedical engineeringScientific reports
researchProduct

Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)

1996

The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surfaces (3D MR-CCM) has been developed for cartilage thickness measurements. Eight cadaveric knee-joint specimens and six volunteers were imaged using a fat-suppressed gradient-echo sequence at a resolution of 2 x 0.31 x 0.31 mm3. Cartilage volumes and topographical thickness maps were obtained and compared with those derived from anatomical sections by image analysis. The deviation …

AdultCartilage ArticularMalemusculoskeletal diseasesAccuracy and precisionMaterials scienceKnee JointCoefficient of variationKnee JointmedicineHumansRadiology Nuclear Medicine and imagingJoint (geology)AgedAged 80 and overObserver Variationmedicine.diagnostic_testCartilageReproducibility of ResultsMagnetic resonance imagingAnatomyMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureFemalePatellaCadaveric spasmBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Importance of Patella, Quadriceps Forces, and Depthwise Cartilage Structure on Knee Joint Motion and Cartilage Response During Gait

2015

In finite-element (FE) models of the knee joint, patella is often omitted. We investigated the importance of patella and quadriceps forces on the knee joint motion by creating an FE model of the subject's knee. In addition, depthwise strains and stresses in patellar cartilage with different tissue properties were determined. An FE model was created from subject's magnetic resonance images. Knee rotations, moments, and translational forces during gait were recorded in a motion laboratory and used as an input for the model. Three material models were implemented into the patellar cartilage: (1) homogeneous model, (2) inhomogeneous (arcadelike fibrils), and (3) random fibrils at the superficia…

AdultCartilage ArticularMalemusculoskeletal diseasesquadricepsMaterials science0206 medical engineeringShear forceBiomedical Engineering02 engineering and technologyOsteoarthritisKnee Jointmedicine.disease_causegaitModels BiologicalQuadriceps MuscleWeight-bearingWeight-Bearingknee joint03 medical and health sciences0302 clinical medicineTensile StrengthPhysiology (medical)Collagen networkfinite-element modelsmedicineHumansComputer SimulationRange of Motion Articularta315Orthodonticsta114Cartilage030229 sport sciencesmusculoskeletal systemmedicine.disease020601 biomedical engineeringmedicine.anatomical_structurepatellaPatellaStress MechanicalRange of motionhuman activitiesMuscle ContractionJournal of Biomechanical Engineering
researchProduct

Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.

1997

Abstract Data on articular cartilage thickness in the living are important for the design of computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during arthroscopy. A non-invasive method for measuring cartilage thickness in living subjects is, however, not available. A technique based on magnetic resonance imaging has therefore been tested for assessing articular cartilage thickness throughout joint surfaces. The accuracy is determined by comparing cartilage thickness maps obtained from three patellar specimens with a…

AdultCartilage ArticularMaterials scienceKnee JointBiomedical EngineeringBiophysicsContrast MediaArticular cartilageModels BiologicalArthroscopyTriiodobenzoic AcidsmedicineCadaverImage Processing Computer-AssistedHumansOrthopedics and Sports MedicineJoint (geology)Ultrasonographymedicine.diagnostic_testbusiness.industryCartilageRehabilitationArthroscopyUltrasoundMagnetic resonance imagingPatellaCartilage thicknessMiddle AgedImage EnhancementMagnetic Resonance ImagingRadiographic Image Enhancementmedicine.anatomical_structurePatellaStress MechanicalbusinessTomography X-Ray ComputedBiomedical engineeringJournal of biomechanics
researchProduct

A multi-joint lower-limb tracking-trajectory test for the assessment of motor coordination.

2005

This study aimed to determine whether a lower-limb trajectory-tracking task performed on a leg press machine, that is commonly adopted in both rehabilitation and resistance training settings, could yield reliable assessment of motor coordination in able-bodied individuals. Twenty-two female subjects allocated to two experimental groups were tested and retested after 48-72 h. Group A was fully familiarized with the experimental procedures before each test while group B received only verbal instructions. The unilateral coordination test consisted of target tracking during a simulated half squat including eccentric and concentric actions. In both groups, tracking error showed significant test-…

AdultCommunicationmedicine.medical_specialtyKnee JointPsychometricsbusiness.industryGeneral NeuroscienceMusculoskeletal Physiological PhenomenaMotor controlSquatConcentricMotor coordinationPhysical medicine and rehabilitationLower ExtremityEccentricMedicineHumansFemaleRange of Motion ArticularMotor learningbusinessLeg pressRange of motionPsychomotor PerformanceNeuroscience letters
researchProduct